The heat pump for ventilation and dehumidification in indoor swimming-pools (hereinafter only the WPLE unit) is a compact air-system device integrated with a complete cooling circuit containing working filling consisting of cooling agent and oil.The WPLE unit consists of two sections transported separately which are put together to a single aggregate during installation.
The heat pump for ventilation and dehumidification in indoor swimming-pools (hereinafter only the WPLE unit) is a compact air-system device integrated with a complete cooling circuit containing working filling consisting of cooling agent and oil. The WPLE unit consists of two sections transported separately which are put together to a single aggregate during installation.
The first (entry) section, the „energetic“ one is the main functional part. It provides filtration both of internal and external air (the filtration class of EU 7) on the one hand and on the other hand primarily all energetic functions, i.e. heat recovery, air dehumidification and additional heating including operation of a complete cooling circuit or more precisely the heat pump which is a part of this section. It also includes an electric switchboard with power wiring and a control system. The second (output) section, the „fan“ one, contains fans transporting both supplied and discharged air.
The advantages of the split structure are variability and flexibility, i.e. especially easier transportation and possibility to offer a „left“ or a „right“ model.
When external air ducts, the heating water distribution line, the mains, external sensors and the external control panel have been connected and after connection its draining pipeline (condensed air humidity) to sewer line inlet, the WPLE unit is ready to putting into operation.
a) Ventilation
In its function of ventilation the unit operates with 100% of fresh air with heat recovery as standard. In summertime operation, the unit can run without the heat recovery.
b) Dehumidification
In its function of dehumidification the unit operates either with circulation air purely or circulation air mixed with a certain portion (a nominal value of 30%) of sucked fresh air; heat recovery is standard. In summertime operation, the unit can be operated without the heat recovery.
WPLE 2250 - ventilation performance of 2250 m3 /h
WPLE 3000 - ventilation performance of 3000 m3 /h
WPLE 3900 - ventilation performance of 3900 m3 /h
WPLE 5200 - ventilation performance of 5200 m3 /h
WPLE 2250 / WT - ventilation performance of 2250 m3 /h, swimming-pool water warming
WPLE 3000 / WT - ventilation performance of 3000 m3 /h, swimming-pool water warming
WPLE 3900 / WT - ventilation performance of /h, swimming-pool water warming
WPLE 5200 / WT - ventilation performance of 5200 m3 /h, swimming-pool water warming